About the Crystal Load Capacitor & PPM Calculator
Choose the two load capacitors for a crystal oscillator so the crystal sees its rated load capacitance, allowing for stray capacitance in the PCB. Then convert a ppm tolerance to a frequency window, or a measured frequency to a ppm error.
The tolerance window shows where your measured frequency lands.
Frequently asked questions
How do I choose crystal load capacitors?
The crystal sees CL = C1·C2/(C1 + C2) + C_stray. With equal capacitors, C1 = C2 = 2·(CL − C_stray). A 12 pF crystal with 3 pF stray needs 18 pF capacitors.
How much stray capacitance should I assume?
2 to 5 pF is typical for the pins, pads and traces of a compact layout.
How do I convert ppm to Hz?
Δf = f × ppm / 1,000,000. A 16 MHz crystal at ±20 ppm can be off by ±320 Hz.
Related calculators
- Ohm's Law Calculator & LED Resistor CalculatorCircuits
- Series & Parallel Resistor, Capacitor, Inductor CalculatorCircuits
- Pi, T & Bridged-T Attenuator CalculatorCircuits
- Reactance & LC Resonant Frequency CalculatorCircuits
- PCB Trace SimulatorSimulator
- PCB Trace Impedance CalculatorSignal integrity
- Differential Pair Impedance & Crosstalk CalculatorSignal integrity
- Effective Dielectric Constant Calculator (εeff)Signal integrity
- Rise Time to Bandwidth & Critical Trace Length CalculatorSignal integrity
- Frequency to Wavelength Calculator for PCBsSignal integrity