About the PCB Trace Fusing Current Calculator (Onderdonk)
Estimate the current that will melt a copper trace open in a given time using Onderdonk's equation. It is useful for checking whether a trace survives a short-circuit pulse, or for sizing a deliberate PCB fuse.
The animation replays the trace heating to failure at the fusing current.
Frequently asked questions
What is Onderdonk's equation?
I = A·√(log₁₀(1 + (Tm − Ta)/(234 + Ta)) / (33·t)), with A in circular mils, Tm the melting point of copper and t in seconds. It assumes the heat stays in the copper.
Can a PCB trace be used as a fuse?
It can for fault protection, but the fusing point varies with board, copper and ambient conditions, so a real fuse is more predictable. Use this as an estimate only.
Why is the fusing current so much higher than the rated current?
Rated current keeps the temperature rise small over long periods. Fusing current melts copper in seconds or less, which needs far more power.