Signal integrity

PDN Target Impedance & Plane Capacitance Calculator

Free power delivery network calculator: target impedance from rail voltage, ripple and transient current, plus power-ground plane capacitance and reactance.

About the PDN Target Impedance & Plane Capacitance Calculator

Find the target impedance your power delivery network must stay under, from the rail voltage, allowed ripple and the transient part of the load current. Then see how much capacitance a power and ground plane pair adds and at which frequencies it meets the target on its own.

The impedance plot shows the plane's reactance against your target and the plane pair's first cavity resonance.

Frequently asked questions

How is PDN target impedance calculated?

Ztarget = (rail voltage × allowed ripple) / (transient current). A 1.0 V rail with 3 % ripple and a 5 A transient needs about 6 mΩ.

How much capacitance does a plane pair give?

C = ε₀·εr·A/d. Two planes overlapping 50 × 50 mm with 0.1 mm of FR-4 between them give about 1 nF.

Why do I still need decoupling capacitors?

Plane capacitance is small and only meets low target impedances at high frequency. Bulk and ceramic capacitors cover the lower frequencies.

Related calculators

PCB WorkbenchFree, visual PCB design and electronics calculators.
Designed and built by Ciarán McDermott
© 2026 Ciarán McDermott. All rights reserved.

Results are engineering estimates from published formulas and standards. Check critical designs with your fabricator or a field solver before production.