About the RC Time Constant & Capacitor Discharge Calculator

Find the RC time constant τ, the time to reach 63, 95 and 99 % of the supply and the energy stored in the capacitor. In discharge mode, find how long a capacitor takes to fall to a safe voltage through a bleed resistor, or the largest bleed resistor for a given time.

The voltage curve is plotted with a moving marker.

Frequently asked questions

What is the RC time constant?

τ = R × C, the time to charge to about 63 % of the final voltage. After 5τ the capacitor is within 1 % of its final value.

How long does a capacitor take to discharge?

t = R·C·ln(V₀/V_final). A 100 µF capacitor at 400 V through 10 kΩ reaches 50 V in about 2.1 s.

What voltage is safe to touch?

Below about 50 V DC is commonly treated as safe extra-low voltage, but follow the standard that applies to your product.