About the AWG Wire Gauge Chart, Drill Sizes & Screw Clearance
Look up American Wire Gauge sizes from 0000 to 40 with diameter, area in mm² and circular mils, resistance per metre or foot and chassis ampacity, and calculate the voltage drop for your wire length and current.
Reference charts for metric drills and common metric and UNC screws with clearance holes are included.
Frequently asked questions
What is the diameter of 22 AWG wire?
About 0.64 mm (25 mil), with roughly 53 mΩ per metre of resistance.
How do I calculate wire voltage drop?
V = I × R, with R the wire's resistance per length times its length. Remember to include both the supply and return conductors.
What clearance hole does an M3 screw need?
A 3.2 mm hole for a normal fit, or 3.4 mm for a looser fit.
Related calculators
- mil to mm, dBm to Volts, Polar & Copper Weight ConverterReference
- PCB Trace SimulatorSimulator
- PCB Trace Impedance CalculatorSignal integrity
- Differential Pair Impedance & Crosstalk CalculatorSignal integrity
- Effective Dielectric Constant Calculator (εeff)Signal integrity
- Rise Time to Bandwidth & Critical Trace Length CalculatorSignal integrity
- Frequency to Wavelength Calculator for PCBsSignal integrity
- PDN Target Impedance & Plane Capacitance CalculatorSignal integrity
- PCB Trace Width CalculatorCurrent and heat
- PCB Trace Fusing Current Calculator (Onderdonk)Current and heat